Spectral analysis

Frequency monitoring for unit

Purpose

Frequency monitoring of your unit’s generator, turbine, and shaft-line system. Catch their characteristics and track changes in these to understand specific wear for the main components. 

 

Reduce downtime caused by damage and corrective maintenance. Improve ability to do preventive maintenance. 

Signals / measurements

Inputs

Quality

How

X-direction proximity for shaft, all bearings  

Resolution up to 2000Hz​

Blink-counter aggregate energy meter.​
Protocol (MQTT etc.)aggr

Y-direction proximity for shaft, all bearings 

Resolution up to 2000Hz​

Blink-counter aggregate energy meter.​
Protocol (MQTT etc.)aggr

Phase 

Resolution up to 2000Hz​20-200Hz​

Pressure sensor 4-20mA​

(Optional – Bearing housing accelerometer) 

Results

Results

Plots: For all predefined frequencies of interest. 

Technical summary

Typically, analog signals from existing sensors for bearings and shaft are copied instead of mounting new sensors.   

Both frequencies that are harmonics of the turning speed and other frequency-sweeps that are induced by flow vortexes can be monitored. 

You might also like

Generator rotor flux
Monitor magnetic flux for rotor poles
Generator rotor temperature
Monitor temperature for each rotor pole
Shaft and bearing monitoring
Monitor alignment and imbalances
Status Inference
Identify process statuses without digital I/O